The use of automatic compression device on the cardiopulmonary resuscitation by lifeguards

  1. Abelairas Gómez, Cristian
  2. Barcala Furelos, Roberto J.
  3. García Soidán, José Luis
  4. López García, Sergio
  5. Romo Pérez, Vicente
Zeitschrift:
European Journal of Human Movement

ISSN: 0214-0071 2386-4095

Datum der Publikation: 2012

Nummer: 29

Seiten: 17-28

Art: Artikel

Andere Publikationen in: European Journal of Human Movement

Zusammenfassung

The purpose of the study was to analyse how the auxiliary rescue material and the automatic compression mechanism influence cardiopulmonary resuscitation (CPR). The sample of our research is composed of a group of 78 lifeguards (50 men and 28 women). An initial test was performed which consisted in the execution of 5 min of CPR. The sample was divided in two groups. Each group performed a second test; water rescue and subsequent 5 min of CPR. One group performed the rescue without material and manual CPR. The other one, the water rescue with flippers and rescue tube and the CPR with an automatic compression mechanism. The use of the automatic compression mechanism improves the conditions in the correct compressions (p < 0.001). There was no significant difference in the correct breathing (p = 0.56). During the water rescue men were faster when compared to women (p < 0.001). When the rescuers are equipped with flippers and a rescue tube, the gender is not as significant (p = 0.26). The rescue material is a key to reduce the time water rescue, and the automatic compression mechanism to improve the quality CPR.

Bibliographische Referenzen

  • Adelborg, K., Dalgas, C., Grove, E. L., Jørgensen, C., Al-Mashhadi, R. H. & Løfgren, B. (2011). Mouth-to-mouth ventilation is superior to mouth-to-pocket mask and bag-valve-mask ventilation during lifeguard CPR: A randomized study. Resuscitation, 82(5), 618-622.
  • Centers for Disease Control and Prevention - National Center for Injury Prevention and Control (2012). k. CDC-NCIPC, Atlanta.
  • Claesson, A., Svensson, L., Silfverstolpe, J. & Herlitz, J. (2008). Characteristics and outcome among patients suffering out-of-hospital cardiac arrest due to drowning. Resuscitation, 76(3), 381-387.
  • Claesson, A., Karlsson, T., Thorén, A. & Herlitz, J. (2011). Delay and performance of cardiopulmonary resuscitation in surf lifeguards after simulated cardiac arrest due to drowning. American Journal of Emergency Medicine, 29(9), 1044-1050.
  • Gulbin J.P., Fell, J.W. & Gaffney, P.T. (1996). A physiological profile of elite surf ironmen, full time lifeguards and patrolling surf life savers. Australian Journal of Science and Medicine in Sport, 28, 86-90.
  • Halperin, H., & Carver, D.J. (2010). Mechanical CPR devices. Signa Vitae, 5(1), 69-73
  • Heidenreich, J. W., Bonner, A. & Sanders, A. B. (2012). Rescuer fatigue in the elderly: Standard vs. hands-only CPR. Journal of Emergency Medicine, 42(1), 88-92.
  • Herlitz, J., Svensson, L., Engdahl, J., Ängquist, K., Silfverstolpe, J., & Holmberg, S. (2006). Association between interval between call for ambulance and return of spontaneous circulation and survival in out-of-hospital cardiac arrest. Resuscitation, 71(1), 40-46.
  • International Life Saving Federation (2010). Appendix 10: International surf lifeguard. Minimum recommended competencies. ILS, Leuven. (Accessed 29 May 2012, at http://www.ilsf.org/sites/ilsf.org/files/filefield/APP%2010%20ILS%20Lifeguard%20Surf.pdf).
  • Josep, O., Rimbau, P., Bertran, C., Juvinya, D., & Carreras, V. (2010). Is it possible to carry out high-quality cardiopulmonary resuscitation (CPR) for a period of 10 minutes? Resuscitation, 81(2), S52.
  • Koster, R.W., Baubin, M.A., Bossaert, L.L., Caballero, A., Cassan, P., Castrén, M., et al. (2010). European Resuscitation Council Guidelines for Resuscitation 2010 Section 2. Adult basic life support and use of automated external defibrillators. Resuscitation, 81, 1277-1292.
  • Laffite, L.P., Vilas-Boas, J.P., Demarle, A., Silva, J., Fernandes, R. & Billat V.L. (2004). Changes in physiological and stroke parameters during a maximal 400-m free swimming test in elite swimmers. Canadian Journal of Applied Physiology, 29, S17-S31.
  • Lyon, R.M., Cobbe, S.M., Bradley, J.M. & Grubb, N.R. (2004). Surviving out of hospital cardiac arrest at home: A postcode lottery? Emergency Medicine Journal, 21(5), 619-624.
  • MacKay, M. and Vincenten , J. (2009). Child safety report card 2009: Europe Summary for 24 Countries. European Child Safety Alliance-Eurosafe, Amsterdam.
  • Neset, A., Birkenes, T.S., Furunes, T., Myklebust, H., Mykletun, R. J., Odegaard, S. et al. (2012). A randomized trial on elderly laypersons’ CPR performance in a realistic cardiac arrest simulation. Acta Anaesthesiologica Scandinavica, 56(1), 124-131.
  • Nolan, J.P., Soar, J., Zideman, D.A., Biarent, D., Bossaert, L.L., Deakin, C. et al. (2010). European resuscitation council guidelines for resuscitation 2010 section 1. executive summary. Resuscitation, 81, 1219-1276.
  • Ochoa, F.J., Ramalle-Gómara, E., Lisa, V. & Saralegui, I. (1998). The effect of rescuer fatigue on the quality of chest compressions. Resuscitation, 37(3), 149-152.
  • Ong, M.E., Mackey, K.E., Zhang, Z.C., Tanaka, H., Ma, M.H., Swor, R. et al. (2012). Mechanical CPR devices compared to manual CPR during out-of-hospital cardiac arrest and ambulance transport: a systematic review. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 20, 39.
  • Prieto, J.A., del Valle, M., González, V., Montoliu, M.A., Nistal, P., Egocheaga, J. et al. (2010). Physiological response of beach lifeguards in a rescue simulation with surf. Ergonomics, 53(9), 1140-1150.
  • Perkins, G. D. (2005). In-water resuscitation: A pilot evaluation. Resuscitation, 65(3), 321-324.
  • Reilly, T., Wooler, A., & Tipton M. (2006). Occupational fitness standards for beach lifeguards. Phase 1: The physiological demands of beach lifeguarding. Occupational Medicine, 56,6-11.
  • Russo, S.G., Neumann, P., Reinhardt, S., Timmermann, A., Nikas, A., Quintel, M. et al. (2011). Impact of physical fitness and biometric data on the quality of external chest compression: A randomised, crossover trial. BMC Emergency Medicine, 11:20.
  • Smekal, D., Johansson, J., Huzevka, T., & Rubertsson, S. (2009). No difference in autopsy detected injuries in cardiac arrest patients treated with manual chest compressions compared with mechanical compressions with the LUCAS device - A pilot study. Resuscitation, 80, 1104-1107.
  • Soar, J., Perkins, G.D., Abbas, G., Alfonzo, A., Barelli, A., Bierens, J.J.L.M. et al. (2010). European Resuscitation Council Guidelines for Resuscitation 2010 Section 8. Cardiac arrest in special circumstances: Electrolyte abnormalities, poisoning, drowning, accidental hypothermia, hyperthermia, asthma, anaphylaxis, cardiac surgery, trauma, pregnancy, electrocution. Resuscitation, 81, 1400-1433.
  • Szpilman, D. and Soares, M. (2004). In-water resuscitation - Is it worthwhile? Resuscitation, 63, 25-31. Szpilman, D., Bierens, J.J.L.M., Handley, A.J. and Orlowski, J.P. (2012). Drowning. New England Journal of Medicine, 366, 2102-2110.
  • Towner, E. & Scott, I. (2008). Child injuries in context. In: World report on child injury prevention. Ed: Peden, M., Oyegbite, K., Ozanne, J., Hyder, A.A., Branche, C., Fazlur, A.K.M., et al. Geneva: UNICEF. 1-30.
  • Travers, A.H., Rea, T.D., Bobrow, B.J., Edelson, D.P., Berg, R.A., Sayre, M.R., et al. (2010). Part 4: CPR Overview: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitacion and Emergency Cardiovascular Care. Circulation, 122, s676-84.
  • The United States Lifeguard Standards Coalition (2011). United States Lifeguard Standars: An Evidence-Based Review and Report by the United States Lifeguard Standards Coalition. International Journal of Aquatic Research and Education, 5(1), 61-129.
  • Van Hoeyweghen, R.J., Bossaert, L.L., Mullie A., Calle, P. et al. (1993). Quality and efficiency of bystander CPR. Belgian Cerebral Resuscitation Study Group. Resuscitation, 26(1), 47-52.
  • Weisfeldt, M.L., Sitlani, C.M., Ornato, J.P., Rea, T., Aufderheide, T.P., Davis, D. et al. (2010). Survival after application of automatic external defibrillators before arrival of the emergency medical system. Evaluation in the resuscitation outcomes consortium population of 21 million. Journal of American College of Cardiololgy, 55, 1713-1720.